CHEVMODE=value1, BNDSELL=value1, RESTBS=value1, REFSEL=value1, RESPOS=value1, BNDSELU=value1, BWDCH=value1, ICLSEL=value1, BWDEN=value1, BNDSELX=value1, RESREG=value1, SYNC=value1
Channel Ctrl. Reg.
ICLSEL | Input Class Select 0 (value1): Use group-specific class 0 1 (value2): Use group-specific class 1 2 (value3): Use global class 0 3 (value4): Use global class 1 |
BNDSELL | Lower Boundary Select 0 (value1): Use group-specific boundary 0 1 (value2): Use group-specific boundary 1 2 (value3): Use global boundary 0 3 (value4): Use global boundary 1 |
BNDSELU | Upper Boundary Select 0 (value1): Use group-specific boundary 0 1 (value2): Use group-specific boundary 1 2 (value3): Use global boundary 0 3 (value4): Use global boundary 1 |
CHEVMODE | Channel Event Mode 0 (value1): Never 1 (value2): NCM: If result is inside the boundary band FCM: If result becomes high (above cmp. val.) 2 (value3): NCM: If result is outside the boundary band FCM: If result becomes low (below cmp. val.) 3 (value4): NCM: Always (ignore band) FCM: If result switches to either level |
SYNC | Synchronization Request 0 (value1): No synchroniz. request, standalone operation 1 (value2): Request a synchronized conversion of this channel (only taken into account for a master) |
REFSEL | Reference Input Selection 0 (value1): Standard reference Ground VSS 1 (value2): Alternate reference Ground from CH0 |
BNDSELX | BoundaryExtension 0 (value1): Standard mode: select boundaries via BNDSELU/BNDSELL 1 (value2): Use result reg. GxRES1 as upper boundary 15 (value3): Use result reg. GxRES15 as upper boundary |
RESREG | Result Register 0 (value1): Store result in group result register GxRES0 15 (value2): Store result in group result register GxRES15 |
RESTBS | Result Target for Background Source 0 (value1): Store results in the selected group result register 1 (value2): Store results in the global result register |
RESPOS | Result Position 0 (value1): Store results left-aligned 1 (value2): Store results right-aligned |
BWDCH | Broken Wire Detection Channel 0 (value1): Select VAREF 1 (value2): Select VAGND |
BWDEN | Broken Wire Detection Enable 0 (value1): Normal operation 1 (value2): Additional preparation phase is enabled |